Kampmann GmbH & Co. KG
Katherm NK
Registration Code: 7GQCJB
Holz und Holzwerkstoffe (u. nachw. Rohstoffe)
Metalle
Product description
Trench units are installed along floor-to-ceiling window surfaces in the floor. The Katherm NK provides a comfortable feel-good climate in the room through natural convection. The cooled room air sinks into the floor channel, flows through the water-heated convector and rises as heated air at the window surfaces to then be distributed in the room. The Katherm NK is suitable for full room heating, residual heat coverage and cold air screening. The unit is available in various duct widths, heights and lengths for heating the room as required. The Katherm NK has a convector consisting of round copper pipes with aluminium fins through which hot water flows. The units can also be equipped with an electromechanical control system to regulate the units according to the customer's requirements. The unit components are mounted in a floor trench, which is covered by a roll-up grille or a linear grille. This decorative cover of the trench unit is available in aluminium, brass, stainless steel and wood.The Katherm NK trench unit is used to heat rooms with large window areas. Exemplary areas of application for the unit are hotels, offices, sales and exhibition rooms.
Instructions for use
The units are used to heat all areas of buildings that need to be heated in winter. Within the room to be heated, the unit needs to be connected to the building's heating/ventilation system and to the building's power network. The operating limits and limits of use must be observed.Reference to the DGNB system
ENV1.1 Building life cycle assessment
ENV1.1 Building life cycle assessment
Photochemical ozone creation potential (POCP)
1) Production stage
6,81E-01
- Source
- EPD S-P-07770
- Quality
- [Externally audited specific manufacturer information]
2) Use stage
3,51E-02
- Source
- EPD S-P-07770
- Quality
- [Externally audited specific manufacturer information]
3) End of life stage
1,93E-03
- Source
- EPD S-P-07770
- Quality
- [Externally audited specific manufacturer information]
4) Benefits and loads beyond the system boundries
-4,34E-01
- Source
- EPD S-P-07770
- Quality
- [Externally audited specific manufacturer information]
Unit
kg NMVOC-Equivalent
- Source
- EPD S-P-07770
- Quality
- [Externally audited specific manufacturer information]
Non-renewable primary energy demand (PEne)
1) Production stage
2,09E+03 MJ
- Source
- EPD S-P-07770
- Quality
- [Externally audited specific manufacturer information]
2) Use stage
6,97E+01 MJ
- Source
- EPD S-P-07770
- Quality
- [Externally audited specific manufacturer information]
3) End of life stage
3,58E+00 MJ
- Source
- EPD S-P-07770
- Quality
- [Externally audited specific manufacturer information]
4) Benefits and loads beyond the system boundries
-1,20E+03 MJ
- Source
- EPD S-P-07770
- Quality
- [Externally audited specific manufacturer information]
Renewable primary energy demand (PEe)
1) Production stage
6,25E+02 MJ
- Source
- EPD S-P-07770
- Quality
- [Externally audited specific manufacturer information]
2) Use stage
1,63E+01 MJ
- Source
- EPD S-P-07770
- Quality
- [Externally audited specific manufacturer information]
3) End of life stage
7,30E-02 MJ
- Source
- EPD S-P-07770
- Quality
- [Externally audited specific manufacturer information]
4) Benefits and loads beyond the system boundries
-1,92E+02 MJ
- Source
- EPD S-P-07770
- Quality
- [Externally audited specific manufacturer information]
General life cycle assessment data
Building material class
not relevant
- Source
- Manufacturer
- Quality
- [Unaudited manufacturer specification]
Reference Unit
1 kW
- Source
- EPD S-P-07770
- Quality
- [Externally audited specific manufacturer information]
If necessary, conversion of the reference unit
No conversion necessary
- Source
- Manufacturer
- Quality
- [Unaudited manufacturer specification]
End of life cycle
Metal parts are 76% recycled and 24% disposed of in a landfill, plastic parts are 100% incinerated for heat recovery.
- Source
- EPD S-P-07770
- Quality
- [Externally audited specific manufacturer information]
Useful life
40 years
- Source
- EPD S-P-07770
- Quality
- [Externally audited specific manufacturer information]
Global Warming Potential (GWP)
1) Production stage
1,50E+02
- Source
- EPD S-P-07770
- Quality
- [Externally audited specific manufacturer information]
2) Use stage
4,26E+00
- Source
- EPD S-P-07770
- Quality
- [Externally audited specific manufacturer information]
3) End of life stage
5,80E+00
- Source
- EPD S-P-07770
- Quality
- [Externally audited specific manufacturer information]
4) Benefits and loads beyond the system boundries
-1,02E+02
- Source
- EPD S-P-07770
- Quality
- [Externally audited specific manufacturer information]
Unit
kg CO2-Equivalent
- Source
- EPD S-P-07770
- Quality
- [Externally audited specific manufacturer information]
Eutrophication potential (EP)
1) Production stage
1,97E-01
- Source
- EPD S-P-07770
- Quality
- [Externally audited specific manufacturer information]
2) Use stage
1,47E-02
- Source
- EPD S-P-07770
- Quality
- [Externally audited specific manufacturer information]
3) End of life stage
4,69E-05
- Source
- EPD S-P-07770
- Quality
- [Externally audited specific manufacturer information]
4) Benefits and loads beyond the system boundries
-1,25E-01
- Source
- EPD S-P-07770
- Quality
- [Externally audited specific manufacturer information]
Unit
kg P-Eq. [EP-freshwater]; kg N-Eq. [EP-marine]; mol N-Eq. [EP-terrestrial]
- Source
- EPD S-P-07770
- Quality
- [Externally audited specific manufacturer information]
Acidification potential (AP)
1) Production stage
2,20E+00
- Source
- EPD S-P-07770
- Quality
- [Externally audited specific manufacturer information]
2) Use stage
1,87E-01
- Source
- EPD S-P-07770
- Quality
- [Externally audited specific manufacturer information]
3) End of life stage
1,90E-03
- Source
- EPD S-P-07770
- Quality
- [Externally audited specific manufacturer information]
4) Benefits and loads beyond the system boundries
-1,47E+00
- Source
- EPD S-P-07770
- Quality
- [Externally audited specific manufacturer information]
Unit
mol H+- Equivalent
- Source
- EPD S-P-07770
- Quality
- [Externally audited specific manufacturer information]
Ozone Depletion Potential (ODP)
1) Production stage
1,03E-05
- Source
- EPD S-P-07770
- Quality
- [Externally audited specific manufacturer information]
2) Use stage
2,79E-07
- Source
- EPD S-P-07770
- Quality
- [Externally audited specific manufacturer information]
3) End of life stage
4,71E-08
- Source
- EPD S-P-07770
- Quality
- [Externally audited specific manufacturer information]
4) Benefits and loads beyond the system boundries
-6,14E-06
- Source
- EPD S-P-07770
- Quality
- [Externally audited specific manufacturer information]
Unit
kg CFC11-Equivalent
- Source
- EPD S-P-07770
- Quality
- [Externally audited specific manufacturer information]
ENV2.2 Potable water demand and waste water volume
ENV2.2 Potable water demand and waste water volume
Installation-specific connected load
Flow rate (for sanitary fittings)
not relevant l/sec
- Source
- Manufacturer
- Quality
- [Unaudited manufacturer specification]
Average flushing volume (of the sanitary equipment)
not relevant l/flush
- Source
- Manufacturer
- Quality
- [Unaudited manufacturer specification]
ECO1.1 Life cycle costs
ECO1.1 Life cycle costs
Actual useful life
40 years
- Source
- EPD S-P-07770
- Quality
- [Externally audited specific manufacturer information]
PRO1.4 Ensuring sustainability aspects in tendering and contracting
PRO1.4 Ensuring sustainability aspects in tendering and contracting
Tender textes
Product-related tender texts available, reference to EPD and registration in the DGNB Navigator in the tender texts.
- Source
- Tender texts Katherm NK
- Quality
- [Externally audited specific manufacturer information]
PRO2.5 Preparation of sustainable use
PRO2.5 Preparation of sustainable use
Maintenance, inspection, operating and care instructions
Yes, included in assembly instructions.
- Source
- Assembly instructions Katherm NK
- Quality
- [Unaudited manufacturer specification]
SOC1.2 Indoor air quality
SOC1.2 Indoor air quality
Indoor hygiene - volatile organic compounds VOCs
Formaldehyde concentration
- Source
- Manufacturer
- Quality
- [Unaudited manufacturer specification]
Other emission tests / labels
not relevant
- Source
- Manufacturer
- Quality
- [Unaudited manufacturer specification]
TVOC value
- Source
- Manufacturer
- Quality
- [Unaudited manufacturer specification]
Approval test according to AgBB scheme is available
- Source
- Manufacturer
- Quality
- [Unaudited manufacturer specification]
SOC1.3 Acoustic comfort
SOC1.3 Acoustic comfort
Rated building sound insulation value R`w
not relevant dB
- Source
- Manufacturer
- Quality
- [Unaudited manufacturer specification]
SOC1.4 Visual comfort
SOC1.4 Visual comfort
Colour rendering
Color rendering index Ra of artificial lighting
not relevant
- Source
- Manufacturer
- Quality
- [Unaudited manufacturer specification]
TEC1.3 Quality of the building envelope
TEC1.3 Quality of the building envelope
Class of air permeability (joint permeability)
00000000-0000-0000-0000-000000000000
- Source
- Manufacturer
- Quality
- [Unaudited manufacturer specification]
Heat transfer coefficient U
not relevant W/(m²K)
- Source
- Manufacturer
- Quality
- [Unaudited manufacturer specification]
Manufacturer note
Note on document download
All documents mentioned in this product profile (technical catalogue, environmental product declaration (EPD), assembly instructions) are available in their current version in the document download on the Kampmann GmbH & Co. KG website.Note on LCA data
The LCA data given were calculated according to the specifications of the EN 15804:2012+A2:2019 standard.Contact the manufacturer
Kampmann GmbH & Co. KG
Kampmann GmbH & Co. KG
Friedrich-Ebert-Straße 128-130 49811 Lingen (Ems)
Related products from this manufacturer
#EZ9W3J
Venkon XL - Baugröße 2
Kampmann GmbH & Co. KG
In Komfortgebäuden aller Art mit hohem Heiz- und Kühlbedarf sowie hohem Raumnutzer-Anspruch kommen Fan Coils zum Einsatz. Der Fan Coil Venkon XL ist in vier Baugrößen für jede Anwendung und jedes zu kühlende und/oder zu beheizende Gebäude erhältlich.…