Kampmann GmbH & Co. KG
KaCompact KG - Baugröße 15
Registration Code: 6B42WR
Metalle
Product description
The KaCompact KG ensures central and compact ventilation with heat recovery and thus the best climate in existing and new buildings. Example areas of application include restaurants and office buildings, schools or nursery schools. The compact ventilation device is available in four standardized sizes, which differ in the nominal air flow. A highly efficient counterflow heat exchanger incorporated in the KaCompact KG ensures that the thermal energy is recovered from the extract air and transferred to the supply air. Energy-efficient EC radial fans are also installed in the device. The air volume of the KaCompact KG can be continuously regulated or controlled via the integrated control or via on-site control. The KaCompact KG has been designed also in accordance with the requirements of the VDI 6022 revision concept, so that hygienically perfect air conditioning is guaranteed even after years. In addition, the device meets the requirements of the Ecodesign Directive (ErP).Instructions for use
The units are only designed for ventilation with heat recovery and heating or cooling of the air for installation in frost-free and dry interior spaces. Within the room to be heated, the unit needs to be connected to the building's heating/cooling/ventilation system and to the building's sewage system and power grid. Any sound-absorbing measures and insulation of the air ducts must be put in place (on site). The connection to the air duct is sound-decoupled by the insulating spigots fitted. It is decoupled from the floor by the unit feet. The units cannot be divided. The operating limits and limits of use described in the installation instructions must be observed.Reference to the DGNB system
ENV1.1 Building life cycle assessment
ENV1.1 Building life cycle assessment
Photochemical ozone creation potential (POCP)
1) Production stage
4,87E+00
- Source
- EPD-IES-0015167
- Quality
- [Externally audited specific manufacturer information]
2) Use stage
1,29E-01
- Source
- EPD-IES-0015167
- Quality
- [Externally audited specific manufacturer information]
3) End of life stage
3,07E-02
- Source
- EPD-IES-0015167
- Quality
- [Externally audited specific manufacturer information]
4) Benefits and loads beyond the system boundries
-2,02E+00
- Source
- EPD-IES-0015167
- Quality
- [Externally audited specific manufacturer information]
Unit
kg NMVOC-Equivalent
- Source
- EPD-IES-0015167
- Quality
- [Externally audited specific manufacturer information]
Non-renewable primary energy demand (PEne)
1) Production stage
1,47E+04 MJ
- Source
- EPD-IES-0015167
- Quality
- [Externally audited specific manufacturer information]
2) Use stage
5,56E+02 MJ
- Source
- EPD-IES-0015167
- Quality
- [Externally audited specific manufacturer information]
3) End of life stage
5,86E+01 MJ
- Source
- EPD-IES-0015167
- Quality
- [Externally audited specific manufacturer information]
4) Benefits and loads beyond the system boundries
-5,66E+03 MJ
- Source
- EPD-IES-0015167
- Quality
- [Externally audited specific manufacturer information]
Renewable primary energy demand (PEe)
1) Production stage
2,79E+03 MJ
- Source
- EPD-IES-0015167
- Quality
- [Externally audited specific manufacturer information]
2) Use stage
7,10E+01 MJ
- Source
- EPD-IES-0015167
- Quality
- [Externally audited specific manufacturer information]
3) End of life stage
5,43E+00 MJ
- Source
- EPD-IES-0015167
- Quality
- [Externally audited specific manufacturer information]
4) Benefits and loads beyond the system boundries
-1,28E+03 MJ
- Source
- EPD-IES-0015167
- Quality
- [Externally audited specific manufacturer information]
General life cycle assessment data
Building material class
not relevant
- Source
- EPD-IES-0015167
- Quality
- [Externally audited specific manufacturer information]
Reference Unit
1 unit
- Source
- EPD-IES-0015167
- Quality
- [Externally audited specific manufacturer information]
If necessary, conversion of the reference unit
No conversion necessary.
- Source
- EPD-IES-0015167
- Quality
- [Externally audited specific manufacturer information]
End of life cycle
The end of life is modeled according to the JRC Report, Annex C V2.1.
- Source
- EPD-IES-0015167
- Quality
- [Externally audited specific manufacturer information]
Useful life
20 years
- Source
- EPD-IES-0015167
- Quality
- [Externally audited specific manufacturer information]
Global Warming Potential (GWP)
1) Production stage
1,10E+03
- Source
- EPD-IES-0015167
- Quality
- [Externally audited specific manufacturer information]
2) Use stage
2,79E+01
- Source
- EPD-IES-0015167
- Quality
- [Externally audited specific manufacturer information]
3) End of life stage
4,20E+01
- Source
- EPD-IES-0015167
- Quality
- [Externally audited specific manufacturer information]
4) Benefits and loads beyond the system boundries
-4,50E+02
- Source
- EPD-IES-0015167
- Quality
- [Externally audited specific manufacturer information]
Unit
kg CO2-Equivalent
- Source
- EPD-IES-0015167
- Quality
- [Externally audited specific manufacturer information]
Eutrophication potential (EP)
1) Production stage
6,56E-02; 1,65E+00; 1,19E+01
- Source
- EPD-IES-0015167
- Quality
- [Externally audited specific manufacturer information]
2) Use stage
2,06E-03; 2,82E-02; 3,34E-01
- Source
- EPD-IES-0015167
- Quality
- [Externally audited specific manufacturer information]
3) End of life stage
2,95E-04; 4,17E-02; 7,89E-02
- Source
- EPD-IES-0015167
- Quality
- [Externally audited specific manufacturer information]
4) Benefits and loads beyond the system boundries
-2,37E-02; -3,50E-01; -4,04E+00
- Source
- EPD-IES-0015167
- Quality
- [Externally audited specific manufacturer information]
Unit
kg P-Eq. [EP-freshwater]; kg N-Eq. [EP-marine]; mol N-Eq. [EP-terrestrial]
- Source
- EPD-IES-0015167
- Quality
- [Externally audited specific manufacturer information]
Acidification potential (AP)
1) Production stage
7,82E+00
- Source
- EPD-IES-0015167
- Quality
- [Externally audited specific manufacturer information]
2) Use stage
2,43E-01
- Source
- EPD-IES-0015167
- Quality
- [Externally audited specific manufacturer information]
3) End of life stage
2,66E-02
- Source
- EPD-IES-0015167
- Quality
- [Externally audited specific manufacturer information]
4) Benefits and loads beyond the system boundries
-2,46E+00
- Source
- EPD-IES-0015167
- Quality
- [Externally audited specific manufacturer information]
Unit
mol H+- Equivalent
- Source
- EPD-IES-0015167
- Quality
- [Externally audited specific manufacturer information]
Ozone Depletion Potential (ODP)
1) Production stage
3,56E-05
- Source
- EPD-IES-0015167
- Quality
- [Externally audited specific manufacturer information]
2) Use stage
5,64E-07
- Source
- EPD-IES-0015167
- Quality
- [Externally audited specific manufacturer information]
3) End of life stage
1,44E-06
- Source
- EPD-IES-0015167
- Quality
- [Externally audited specific manufacturer information]
4) Benefits and loads beyond the system boundries
-1,21E-05
- Source
- EPD-IES-0015167
- Quality
- [Externally audited specific manufacturer information]
Unit
kg CFC11-Equivalent
- Source
- EPD-IES-0015167
- Quality
- [Externally audited specific manufacturer information]
ENV2.2 Potable water demand and waste water volume
ENV2.2 Potable water demand and waste water volume
Installation-specific connected load
Flow rate (for sanitary fittings)
not relevant l/sec
- Source
- Manufacturer
- Quality
- [Unaudited manufacturer specification]
Average flushing volume (of the sanitary equipment)
not relevant l/flush
- Source
- Manufacturer
- Quality
- [Unaudited manufacturer specification]
ECO1.1 Life cycle costs
ECO1.1 Life cycle costs
Actual useful life
20 years
- Source
- EPD-IES-0015167
- Quality
- [Externally audited specific manufacturer information]
PRO1.4 Ensuring sustainability aspects in tendering and contracting
PRO1.4 Ensuring sustainability aspects in tendering and contracting
Tender textes
Product-related tender texts available, reference to EPD and registration in the DGNB Navigator in the tender texts.
- Source
- Tender texts KaCompact KG
- Quality
- [Unaudited manufacturer specification]
PRO2.5 Preparation of sustainable use
PRO2.5 Preparation of sustainable use
Maintenance, inspection, operating and care instructions
Yes, included in assembly instructions.
- Source
- Assembly instructions KaCompact KG
- Quality
- [Unaudited manufacturer specification]
SOC1.2 Indoor air quality
SOC1.2 Indoor air quality
Indoor hygiene - volatile organic compounds VOCs
Formaldehyde concentration
- Source
- Manufacturer
- Quality
- [Unaudited manufacturer specification]
Other emission tests / labels
not relevant
- Source
- Manufacturer
- Quality
- [Unaudited manufacturer specification]
TVOC value
- Source
- Manufacturer
- Quality
- [Unaudited manufacturer specification]
Approval test according to AgBB scheme is available
not relevant
- Source
- Manufacturer
- Quality
- [Unaudited manufacturer specification]
SOC1.3 Acoustic comfort
SOC1.3 Acoustic comfort
Rated building sound insulation value R`w
not relevant dB
- Source
- Manufacturer
- Quality
- [Unaudited manufacturer specification]
SOC1.4 Visual comfort
SOC1.4 Visual comfort
Visual contact with the outside
Class of the sun/glare protection with regard to visual contact to the outside
not relevant
- Source
- Manufacturer
- Quality
- [Unaudited manufacturer specification]
Colour rendering
Color rendering index Ra of artificial lighting
not relevant
- Source
- Manufacturer
- Quality
- [Unaudited manufacturer specification]
TEC1.3 Quality of the building envelope
TEC1.3 Quality of the building envelope
Class of air permeability (joint permeability)
not relevant
- Source
- Manufacturer
- Quality
- [Unaudited manufacturer specification]
Heat transfer coefficient U
not relevant W/(m²K)
- Source
- Manufacturer
- Quality
- [Unaudited manufacturer specification]
Contact the manufacturer
Kampmann GmbH & Co. KG
Kampmann GmbH & Co. KG
Friedrich-Ebert-Straße 128-130 49811 Lingen (Ems)
Related products from this manufacturer
#9YS24K
Katherm QK nano
Kampmann GmbH & Co. KG
Unterflurkonvektoren werden entlang von bodentiefen Fensterflächen im Boden montiert. In Kombination mit modernen Heizsystemen kann durch den Katherm QK nano eine effektive und energiesparende Beheizung von Räumen erzielt werden. Die Raumluft wird vo…
#M3HIYA
Katherm QK
Kampmann GmbH & Co. KG
Unterflurkonvektoren werden entlang von bodentiefen Fensterflächen im Boden montiert. In Kombination mit modernen Heizsystemen kann durch den Katherm QK eine effektive und energiesparende Beheizung von Räumen erzielt werden. Die Raumluft wird vom Ven…
#WR7MSF
Venkon - Baugröße 67
Kampmann GmbH & Co. KG
In Komfortgebäuden aller Art mit hohem Heiz- und Kühlbedarf sowie hohem Raumnutzer-Anspruch kommen Fan Coils zum Einsatz. Der Fan Coil Venkon ist in vier Baugrößen erhältlich und kann als Grundgerät flexibel mit Verkleidungen kombiniert werden. Der E…