Ultra Allround - Baugröße 1, teilverkleidet
Registration Code: B66W7Z
Metalle
Product description
The unit heater Ultra Allround is a ceiling-mounted unit for heating, cooling and ventilation of large, high-end interiors, like retail chains, exhibition spaces and retail areas, entrance vestibules and retail outlets. The Ultra Allround product range is available in two sizes. The air is drawn in via the radial fan and blown through the circular heat exchanger into the room. In heating mode, warm air is discharged vertically into the room, and in cooling mode it is distributed horizontally. The heat exchangers are precisely configured for low-temperature operation to achieve the maximum energy-efficient outputs.Instructions for use
The units are only intended to be used for heating and cooling air in frost-free and dry rooms. Within the room, the unit needs to be connected to the building's heating/cooling/ventilation system and to the building's waste water and power network. The operating limits and limits of use described in the installation instructions must be observed.Reference to the DGNB system
ENV1.1 Building life cycle assessment
ENV1.1 Building life cycle assessment
Photochemical ozone creation potential (POCP)
1) Production stage
9,94E-01
- Source
- LCA Ultra Allround size 1, partially cased
- Quality
- [Unaudited manufacturer specification]
2) Use stage
3,39E-02
- Source
- LCA Ultra Allround size 1, partially cased
- Quality
- [Unaudited manufacturer specification]
3) End of life stage
3,83E-03
- Source
- LCA Ultra Allround size 1, partially cased
- Quality
- [Unaudited manufacturer specification]
4) Benefits and loads beyond the system boundries
-2,36E-01
- Source
- LCA Ultra Allround size 1, partially cased
- Quality
- [Unaudited manufacturer specification]
Unit
kg NMVOC-Equivalent
- Source
- LCA Ultra Allround size 1, partially cased
- Quality
- [Unaudited manufacturer specification]
Total use of non-renewable primary energy (PENRT)
1) Production stage
3,58E+03 MJ
- Source
- LCA Ultra Allround size 1, partially cased
- Quality
- [Unaudited manufacturer specification]
2) Use stage
9,15E+01 MJ
- Source
- LCA Ultra Allround size 1, partially cased
- Quality
- [Unaudited manufacturer specification]
3) End of life stage
4,37E+00 MJ
- Source
- LCA Ultra Allround size 1, partially cased
- Quality
- [Unaudited manufacturer specification]
4) Benefits and loads beyond the system boundries
-8,83E+02 MJ
- Source
- LCA Ultra Allround size 1, partially cased
- Quality
- [Unaudited manufacturer specification]
Total use of renewable primary energy (PERT)
1) Production stage
9,15E+02 MJ
- Source
- LCA Ultra Allround size 1, partially cased
- Quality
- [Unaudited manufacturer specification]
2) Use stage
1,31E+01 MJ
- Source
- LCA Ultra Allround size 1, partially cased
- Quality
- [Unaudited manufacturer specification]
3) End of life stage
1,42E-01 MJ
- Source
- LCA Ultra Allround size 1, partially cased
- Quality
- [Unaudited manufacturer specification]
4) Benefits and loads beyond the system boundries
-8,71E+01 MJ
- Source
- LCA Ultra Allround size 1, partially cased
- Quality
- [Unaudited manufacturer specification]
General life cycle assessment data
Building material class
not relevant
- Source
- LCA Ultra Allround size 1, partially cased
- Quality
- [Unaudited manufacturer specification]
Reference Unit
1 unit
- Source
- LCA Ultra Allround size 1, partially cased
- Quality
- [Unaudited manufacturer specification]
If necessary, conversion of the reference unit
No conversion necessary.
- Source
- LCA Ultra Allround size 1, partially cased
- Quality
- [Unaudited manufacturer specification]
End of life cycle
The end of life is modeled according to the JRC Report, Annex C V2.1.
- Source
- LCA Ultra Allround size 1, partially cased
- Quality
- [Unaudited manufacturer specification]
Useful life
20 years
- Source
- LCA Ultra Allround size 1, partially cased
- Quality
- [Unaudited manufacturer specification]
Global Warming Potential (GWP)
1) Production stage
2,22E+02
- Source
- LCA Ultra Allround size 1, partially cased
- Quality
- [Unaudited manufacturer specification]
2) Use stage
5,68E+00
- Source
- LCA Ultra Allround size 1, partially cased
- Quality
- [Unaudited manufacturer specification]
3) End of life stage
1,39E+01
- Source
- LCA Ultra Allround size 1, partially cased
- Quality
- [Unaudited manufacturer specification]
4) Benefits and loads beyond the system boundries
-7,59E+01
- Source
- LCA Ultra Allround size 1, partially cased
- Quality
- [Unaudited manufacturer specification]
Unit
kg CO2-Equivalent
- Source
- LCA Ultra Allround size 1, partially cased
- Quality
- [Unaudited manufacturer specification]
Eutrophication (EP)
1) Production stage
1,40E-02; 2,06E-01; 2,41E+00
- Source
- LCA Ultra Allround size 1, partially cased
- Quality
- [Unaudited manufacturer specification]
2) Use stage
6,59E-04; 7,31E-03; 9,05E-02
- Source
- LCA Ultra Allround size 1, partially cased
- Quality
- [Unaudited manufacturer specification]
3) End of life stage
4,41E-06; 1,75E-03; 1,25E-02
- Source
- LCA Ultra Allround size 1, partially cased
- Quality
- [Unaudited manufacturer specification]
4) Benefits and loads beyond the system boundries
-3,62E-03; -5,45E-02; -6,46E-01
- Source
- LCA Ultra Allround size 1, partially cased
- Quality
- [Unaudited manufacturer specification]
Unit
kg P-Eq. [EP-freshwater]; kg N-Eq. [EP-marine]; mol N-Eq. [EP-terrestrial]
- Source
- LCA Ultra Allround size 1, partially cased
- Quality
- [Unaudited manufacturer specification]
Acidification potential (AP)
1) Production stage
1,56E+00
- Source
- LCA Ultra Allround size 1, partially cased
- Quality
- [Unaudited manufacturer specification]
2) Use stage
8,07E-02
- Source
- LCA Ultra Allround size 1, partially cased
- Quality
- [Unaudited manufacturer specification]
3) End of life stage
2,63E-03
- Source
- LCA Ultra Allround size 1, partially cased
- Quality
- [Unaudited manufacturer specification]
4) Benefits and loads beyond the system boundries
-3,42E-01
- Source
- LCA Ultra Allround size 1, partially cased
- Quality
- [Unaudited manufacturer specification]
Unit
mol H+- Equivalent
- Source
- LCA Ultra Allround size 1, partially cased
- Quality
- [Unaudited manufacturer specification]
Ozone Depletion Potential (ODP)
1) Production stage
4,07E-06
- Source
- LCA Ultra Allround size 1, partially cased
- Quality
- [Unaudited manufacturer specification]
2) Use stage
1,59E-07
- Source
- LCA Ultra Allround size 1, partially cased
- Quality
- [Unaudited manufacturer specification]
3) End of life stage
6,55E-09
- Source
- LCA Ultra Allround size 1, partially cased
- Quality
- [Unaudited manufacturer specification]
4) Benefits and loads beyond the system boundries
-7,07E-07
- Source
- LCA Ultra Allround size 1, partially cased
- Quality
- [Unaudited manufacturer specification]
Unit
kg CFC11-Equivalent
- Source
- LCA Ultra Allround size 1, partially cased
- Quality
- [Unaudited manufacturer specification]
ENV2.2 Potable water demand and waste water volume
ENV2.2 Potable water demand and waste water volume
Installation-specific connected load
Flow rate (for sanitary fittings)
not relevant l/sec
- Source
- Manufacturer
- Quality
- [Unaudited manufacturer specification]
Average flushing volume (of the sanitary equipment)
not relevant l/flush
- Source
- Manufacturer
- Quality
- [Unaudited manufacturer specification]
ECO1.1 Life cycle costs
ECO1.1 Life cycle costs
Actual useful life
20 years
- Source
- LCA Ultra Allround size 1, partially cased
- Quality
- [Unaudited manufacturer specification]
PRO1.4 Ensuring sustainability aspects in tendering and contracting
PRO1.4 Ensuring sustainability aspects in tendering and contracting
Tender textes
Product-related tender texts available, reference to LCA and registration in the DGNB Navigator in the tender texts.
- Source
- Tender texts Ultra Allround
- Quality
- [Unaudited manufacturer specification]
PRO2.5 Preparation of sustainable use
PRO2.5 Preparation of sustainable use
Maintenance, inspection, operating and care instructions
Yes, included in assembly instructions.
- Source
- Assembly instructions Ultra Allround
- Quality
- [Unaudited manufacturer specification]
SOC1.2 Indoor air quality
SOC1.2 Indoor air quality
Indoor hygiene - volatile organic compounds VOCs
Formaldehyde concentration
- Source
- Manufacturer
- Quality
- [Unaudited manufacturer specification]
Other emission tests / labels
not relevant
- Source
- Manufacturer
- Quality
- [Unaudited manufacturer specification]
TVOC value
- Source
- Manufacturer
- Quality
- [Unaudited manufacturer specification]
Approval test according to AgBB scheme is available
not relevant
- Source
- Manufacturer
- Quality
- [Unaudited manufacturer specification]
SOC1.3 Acoustic comfort
SOC1.3 Acoustic comfort
Rated building sound insulation value R`w
not relevant dB
- Source
- Manufacturer
- Quality
- [Unaudited manufacturer specification]
SOC1.4 Visual comfort
SOC1.4 Visual comfort
Visual contact with the outside
Class of the sun/glare protection with regard to visual contact to the outside
not relevant
- Source
- Manufacturer
- Quality
- [Unaudited manufacturer specification]
Colour rendering
Color rendering index Ra of artificial lighting
not relevant
- Source
- Manufacturer
- Quality
- [Unaudited manufacturer specification]
TEC1.3 Quality of the building envelope
TEC1.3 Quality of the building envelope
Class of air permeability (joint permeability)
not relevant
- Source
- Manufacturer
- Quality
- [Unaudited manufacturer specification]
Heat transfer coefficient U
not relevant W/(m²K)
- Source
- Manufacturer
- Quality
- [Unaudited manufacturer specification]
Contact the manufacturer

Kampmann GmbH & Co. KG
Kampmann GmbH & Co. KG
Friedrich-Ebert-Straße 128-130
49811 Lingen (Ems)
Related products from this manufacturer

#PES22M
Katherm HK
Kampmann GmbH & Co. KG
Unterflurkonvektoren werden entlang von bodentiefen Fensterflächen im Boden montiert. Der Katherm HK sorgt für eine bedarfsgerechte Zuführung von gefilterter, beheizter oder gekühlter Umluft in den Raum. Für eine bedarfsgerechte Heizung und Kühlung i…

#EZ9W3J
Venkon XL - Baugröße 2
Kampmann GmbH & Co. KG
In Komfortgebäuden aller Art mit hohem Heiz- und Kühlbedarf sowie hohem Raumnutzer-Anspruch kommen Fan Coils zum Einsatz. Der Fan Coil Venkon XL ist in vier Baugrößen für jede Anwendung und jedes zu kühlende und/oder zu beheizende Gebäude erhältlich.…

#WR7MSF
Venkon - Baugröße 67
Kampmann GmbH & Co. KG
In Komfortgebäuden aller Art mit hohem Heiz- und Kühlbedarf sowie hohem Raumnutzer-Anspruch kommen Fan Coils zum Einsatz. Der Fan Coil Venkon ist in vier Baugrößen erhältlich und kann als Grundgerät flexibel mit Verkleidungen kombiniert werden. Der E…