Kampmann GmbH & Co. KG
Katherm QE 1250 mm
Registration Code: V2A2ET
Quality phase
ENV1.2 Version 2023 Risiken für die lokale Umwelt
QS 4
Metalle
Product description
Katherm QE are the ideal solution when the use of an LPHW convector is impossible or not intended. They stand out on account of their energy-saving and ultra-quiet EC tangential fans combined with high performance electric heating element that provides high heat outputs. Katherm QE are ideal for installation in front of floor-to-ceiling glazing. Equipped with state-of-the-art EC technology, the space is quickly heated up with a low, non-disruptive noise level.Air is drawn in by the fan and routed through the parallel heating element with air baffles. The heated air flows out from the floor trench and rises up and/or provides cold air screening of the window and draught-free warm air circulation in the room, thanks to the recirculation of the air. A separating plate effectively prevents mixing between the air intake and air outlet. The EC tangential fan is controlled by a stepless speed control via an external 0-10 V signal.
The Katherm QE is available in three different lengths for heating the room as required. The unit components are mounted in a floor trench, which is covered by a roll-up grille. This decorative cover of the trench unit is available in aluminium, brass and stainless steel. The Katherm QE trench unit is used to heat rooms with large window areas. Exemplary areas of application for the unit are hotels, offices, sales and exhibition rooms.
Instructions for use
The units are used to heat all areas of buildings that need to be heated in winter. Within the room to be heated, the unit needs to be connected to the building's power network.Reference to the DGNB system
ENV1.1 Building life cycle assessment
ENV1.1 Building life cycle assessment
Photochemical ozone creation potential (POCP)
1) Production stage
2,58E-01
- Source
- EPD S-P-12156
- Quality
- [Externally audited specific manufacturer information]
2) Use stage
2,25E-03
- Source
- EPD S-P-12156
- Quality
- [Externally audited specific manufacturer information]
3) End of life stage
5,92E-04
- Source
- EPD S-P-12156
- Quality
- [Externally audited specific manufacturer information]
4) Benefits and loads beyond the system boundries
-1,72E-01
- Source
- EPD S-P-12156
- Quality
- [Externally audited specific manufacturer information]
Unit
kg NMVOC-Equivalent
- Source
- EPD S-P-12156
- Quality
- [Externally audited specific manufacturer information]
Non-renewable primary energy demand (PEne)
1) Production stage
8,09E+02 MJ
- Source
- EPD S-P-12156
- Quality
- [Externally audited specific manufacturer information]
2) Use stage
9,33E+00 MJ
- Source
- EPD S-P-12156
- Quality
- [Externally audited specific manufacturer information]
3) End of life stage
1,14E+00 MJ
- Source
- EPD S-P-12156
- Quality
- [Externally audited specific manufacturer information]
4) Benefits and loads beyond the system boundries
-5,22E+02 MJ
- Source
- EPD S-P-12156
- Quality
- [Externally audited specific manufacturer information]
Renewable primary energy demand (PEe)
1) Production stage
2,44E+02 MJ
- Source
- EPD S-P-12156
- Quality
- [Externally audited specific manufacturer information]
2) Use stage
2,29E+00 MJ
- Source
- EPD S-P-12156
- Quality
- [Externally audited specific manufacturer information]
3) End of life stage
3,28E-02 MJ
- Source
- EPD S-P-12156
- Quality
- [Externally audited specific manufacturer information]
4) Benefits and loads beyond the system boundries
-1,49E+02 MJ
- Source
- EPD S-P-12156
- Quality
- [Externally audited specific manufacturer information]
General life cycle assessment data
Building material class
not relevant
- Source
- EPD S-P-12156
- Quality
- [Externally audited specific manufacturer information]
Reference Unit
1 unit
- Source
- EPD S-P-12156
- Quality
- [Externally audited specific manufacturer information]
If necessary, conversion of the reference unit
No conversion necessary
- Source
- EPD S-P-12156
- Quality
- [Externally audited specific manufacturer information]
End of life cycle
76% of metal parts are recycled with the remaining 24% going to landfill, while 100% of plastic parts are incinerated for heat recovery.
- Source
- EPD S-P-12156
- Quality
- [Externally audited specific manufacturer information]
Useful life
20 years
- Source
- EPD S-P-12156
- Quality
- [Externally audited specific manufacturer information]
Global Warming Potential (GWP)
1) Production stage
6,14E+01
- Source
- EPD S-P-12156
- Quality
- [Externally audited specific manufacturer information]
2) Use stage
6,34E-01
- Source
- EPD S-P-12156
- Quality
- [Externally audited specific manufacturer information]
3) End of life stage
6,18E-01
- Source
- EPD S-P-12156
- Quality
- [Externally audited specific manufacturer information]
4) Benefits and loads beyond the system boundries
-3,96E+01
- Source
- EPD S-P-12156
- Quality
- [Externally audited specific manufacturer information]
Unit
kg CO2-Equivalent
- Source
- EPD S-P-12156
- Quality
- [Externally audited specific manufacturer information]
Eutrophication potential (EP)
1) Production stage
3,81E-02
- Source
- EPD S-P-12156
- Quality
- [Externally audited specific manufacturer information]
2) Use stage
3,51E-04
- Source
- EPD S-P-12156
- Quality
- [Externally audited specific manufacturer information]
3) End of life stage
1,77E-05
- Source
- EPD S-P-12156
- Quality
- [Externally audited specific manufacturer information]
4) Benefits and loads beyond the system boundries
-2,37E-02
- Source
- EPD S-P-12156
- Quality
- [Externally audited specific manufacturer information]
Unit
kg P-Eq. [EP-freshwater]; kg N-Eq. [EP-marine]; mol N-Eq. [EP-terrestrial]
- Source
- EPD S-P-12156
- Quality
- [Externally audited specific manufacturer information]
Acidification potential (AP)
1) Production stage
4,04E-01
- Source
- EPD S-P-12156
- Quality
- [Externally audited specific manufacturer information]
2) Use stage
3,66E-03
- Source
- EPD S-P-12156
- Quality
- [Externally audited specific manufacturer information]
3) End of life stage
4,64E-04
- Source
- EPD S-P-12156
- Quality
- [Externally audited specific manufacturer information]
4) Benefits and loads beyond the system boundries
-2,59E-01
- Source
- EPD S-P-12156
- Quality
- [Externally audited specific manufacturer information]
Unit
mol H+- Equivalent
- Source
- EPD S-P-12156
- Quality
- [Externally audited specific manufacturer information]
Ozone Depletion Potential (ODP)
1) Production stage
1,49E-06
- Source
- EPD S-P-12156
- Quality
- [Externally audited specific manufacturer information]
2) Use stage
1,87E-08
- Source
- EPD S-P-12156
- Quality
- [Externally audited specific manufacturer information]
3) End of life stage
6,14E-09
- Source
- EPD S-P-12156
- Quality
- [Externally audited specific manufacturer information]
4) Benefits and loads beyond the system boundries
-1,08E-06
- Source
- EPD S-P-12156
- Quality
- [Externally audited specific manufacturer information]
Unit
kg CFC11-Equivalent
- Source
- EPD S-P-12156
- Quality
- [Externally audited specific manufacturer information]
ENV2.2 Potable water demand and waste water volume
ENV2.2 Potable water demand and waste water volume
Installation-specific connected load
Flow rate (for sanitary fittings)
not relevant l/sec
- Source
- Manufacturer
- Quality
- [Unaudited manufacturer specification]
Average flushing volume (of the sanitary equipment)
not relevant l/flush
- Source
- Manufacturer
- Quality
- [Unaudited manufacturer specification]
ECO1.1 Life cycle costs
ECO1.1 Life cycle costs
Actual useful life
20 years
- Source
- EPD S-P-12156
- Quality
- [Externally audited specific manufacturer information]
PRO1.4 Ensuring sustainability aspects in tendering and contracting
PRO1.4 Ensuring sustainability aspects in tendering and contracting
Tender textes
Product-related tender texts available, reference to EPD and registration in the DGNB Navigator in the tender texts.
- Source
- Tender texts Katherm QE
- Quality
- [Unaudited manufacturer specification]
PRO2.5 Preparation of sustainable use
PRO2.5 Preparation of sustainable use
Maintenance, inspection, operating and care instructions
Yes, included in assembly instructions.
- Source
- Assembly instructions Katherm QE
- Quality
- [Unaudited manufacturer specification]
SOC1.2 Indoor air quality
SOC1.2 Indoor air quality
Indoor hygiene - volatile organic compounds VOCs
Formaldehyde concentration
- Source
- Manufacturer
- Quality
- [Unaudited manufacturer specification]
Other emission tests / labels
not relevant
- Source
- Manufacturer
- Quality
- [Unaudited manufacturer specification]
TVOC value
- Source
- Manufacturer
- Quality
- [Unaudited manufacturer specification]
Approval test according to AgBB scheme is available
- Source
- Manufacturer
- Quality
- [Unaudited manufacturer specification]
SOC1.3 Acoustic comfort
SOC1.3 Acoustic comfort
Rated building sound insulation value R`w
not relevant dB
- Source
- Manufacturer
- Quality
- [Unaudited manufacturer specification]
SOC1.4 Visual comfort
SOC1.4 Visual comfort
Visual contact with the outside
Class of the sun/glare protection with regard to visual contact to the outside
- Source
- Manufacturer
- Quality
- [Unaudited manufacturer specification]
Colour rendering
Color rendering index Ra of artificial lighting
not relevant
- Source
- Manufacturer
- Quality
- [Unaudited manufacturer specification]
TEC1.3 Quality of the building envelope
TEC1.3 Quality of the building envelope
Class of air permeability (joint permeability)
not relevant
- Source
- Manufacturer
- Quality
- [Unaudited manufacturer specification]
Heat transfer coefficient U
not relevant W/(m²K)
- Source
- Manufacturer
- Quality
- [Unaudited manufacturer specification]
Manufacturer note
Note on LCA data
The LCA data given were calculated according to the specifications of the EN 15804:2012+A2:2019 standard.Note on document download
All documents mentioned in this product profile (technical catalogue, environmental product declaration (EPD), assembly instructions) are available in their current version in the document download on the Kampmann GmbH & Co. KG website.Contact the manufacturer
Kampmann GmbH & Co. KG
Kampmann GmbH & Co. KG
Friedrich-Ebert-Straße 128-130 49811 Lingen (Ems)
Related products from this manufacturer
#9QPY13
PowerKon LT - Baugröße 2
Kampmann GmbH & Co. KG
Für eine zeitgemäße Gebäudebeheizung ist sowohl in Bestandsgebäuden als auch in Neubauten eine Wärmepumpe essenziell. Entscheidend für die Effizienz der Wärmepumpe sind niedrige Systemtemperaturen. Der PowerKon LT ermöglicht unter diesen Bedingungen …
#0VRWZT
Katherm HK E
Kampmann GmbH & Co. KG
Unterflurkonvektoren werden entlang von bodentiefen Fensterflächen im Boden montiert. Der Katherm HK E sorgt für eine bedarfsgerechte Zuführung von gefilterter, beheizter oder gekühlter Umluft in den Raum. Für eine bedarfsgerechte Heizung und Kühlung…
#E5KI78
KaCompact KG - Baugröße 25
Kampmann GmbH & Co. KG
Der KaCompact KG sorgt für eine zentrale und kompakte Lüftung mit Wärmerückgewinnung und somit für bestes Klima im Bestand- und Neubau. Beispielhafte Einsatzbereiche sind Gastronomien und Bürogebäude, Schulen oder Kitas. Das Kompaktlüftungsgerät ist …